MP-R5M 5 Ribbed Roof Panel with Membrane
It is preferred on low slope roofs where the slope is below %5, such asfactory buildings, industrial buildings, military structures, gricultural structures,sports facilities,construction site buildings, silos, hypermarkets, shopping malls,state buildings and thermal power plants.
Insulation Material |
Fire Class |
Density |
Insulation |
Thermal |
U Value | R Value |
---|---|---|---|---|---|---|
(W/m2K) | (h·ft²·°F/Btu) | |||||
Polyurethane (PUR) |
B s2 d0 (TS EN 13501-1) |
40 (±2)kg/m3 | 40 | 0,022 W/mK | 0,53 | 11 |
50 | 0,43 | 13 | ||||
60 | 0,36 | 16 | ||||
80 | 0,27 | 21 | ||||
100 | 0,22 | 26 | ||||
120 | 0,18 | 31 | ||||
150 | 0,15 | 39 | ||||
180 | 0,12 | 47 | ||||
200 | 0,11 | 52 | ||||
External Sheet | 1.20~1.50mm thick TPO or PVC Membrane | |||||
Internal Sheet | Prepainted Galvanized Steel 0.50-0.60-0.70 mm |
U value calculated due to TS EN 14509.U value converted to American R Value.
Product Name |
Steel Thickness (mm) |
Weight (kg/m2) |
Span Type (mm) |
Span Distance | ||||
---|---|---|---|---|---|---|---|---|
1000 | 1500 | 2000 | 2500 | 3000 | ||||
Max.Distributed Load (kg/m2) | ||||||||
32/250 Corrugated Sheet |
0,40 | 3,77 | Two Span | 341 | 208 | 108 | 58 | 51 |
Multi Span | 393 | 242 | 128 | 70 | 63 | |||
0,50 | 4,71 | Two Span | 421 | 258 | 135 | 72 | 63 | |
Multi Span | 485 | 297 | 162 | 90 | 77 | |||
0,60 | 5,65 | Two Span | 489 | 312 | 163 | 87 | 76 | |
Multi Span | 558 | 356 | 194 | 106 | 94 | |||
0,70 | 6,59 | Two Span | 562 | 364 | 190 | 101 | 91 | |
Multi Span | 641 | 415 | 230 | 124 | 112 |
. Values have been calculated using the allowable “Stress Design” method, taking self weight, imposed loads (wind load) and temperature (Δt=±20ºC) into account.
. If loads are effected as downwards l/200 and l/150 , ıf loads are effected as suction l/150 deflection limits have been used
. Values have been calculated using the steel quality fγ=240 Mpa(Yield Strength).