MP-WH/S Siding Wall Panel

 
 

Panels can be montaged horizontally, vertically or angled and offers unlimited design possibilities with colour options to the designers.


Insulation
Material
Fire
Class
Density
 
Insulation
Thickness (mm)
Thermal
Conductivity (λ)
U Value R Value
(W/m2K) (h·ft²·°F/Btu)
Polyisocyanurate
(PIR)
B s1 d0
(TS EN 13501-1)
42 (±2)kg/m3 40 0.020 W/mK 0,41 14
50 0,35 16
60 0,29 20
External Sheet Prepainted Galvanized Steel/Aluminium 0.35-0.40-0,45-0,50-0,60-0,70 mm
Internal Sheet Prepainted Galvanized Steel/Aluminium 0.30-0.35-0.40-0,45-0,50-0,60-0,70 mm

U value calculated due to TS EN 14509.U value converted to American R Value.

Insulation
Material
Insulation
Thickness
(mm)
External Steel
(mm)
Internal Steel
(mm)
Weight
(kg/m2)
Span Type
(mm)
Span Distance
1000 1500 2000 2500 3000
Max.Distributed Load (kg/m2)
Polyisocyanurate
(PIR)
40 0,5 0,4 10,07 Two Span 331 264 221 186 114
Multi Span 338 271 226 191 121
50 0,5 0,4 10,49 Two Span 406 327 279 239 146
Multi Span 413 336 284 244 153
60 0,5 0,4 10,91 Two Span 498 407 352 309 197
Multi Span 505 417 359 314,5 206

Notes:
. Values have been calculated using the allowable “Stress Design” method, taking self weight, imposed loads (wind load) and temperature (Δt=±20ºC) into account.
. If loads are effected as downwards l/200 and l/150 , ıf loads are effected as suction l/150 deflection limits have been used
. Values have been calculated using the steel quality fγ=240 Mpa(Yield Strength).
. In Panel weight calculations, Polyurethane density is taken as 40 kg/m3 and Polyisocyanurate density is taken as 42 kg/m3.