MP-WH/HS Semi Sinus Wall Panel

 
 

Surface of the panel can be produced as Mesa and Microlined texture. Panels can be montaged horizontally, vertically or angled and offers unlimited design possibilities with colour options to the designers.


Insulation
Material
Fire
Class
Density
 
Insulation
Thickness (mm)
Thermal
Conductivity (λ)
U Value R Value
(W/m2K) (h·ft²·°F/Btu)
Polyurethane
(PUR)
B s2 d0
(TS EN 13501-1)
40 (±2)kg/m3 40 0,022 W/mK 0,52 11
50 0,38 15
60 0,35 16
80 0,29 20
100 0,23 25
120 0,19 30
150 0,15 38
180 0,12 46
200 0,11 51
External Sheet Prepainted Galvanized Steel/Aluminium 0,50-0,60-0,70 mm
Internal Sheet Prepainted Galvanized Steel/Aluminium 0.30-0.35-0.40-0,45-0,50-0,60-0,70 mm

U value calculated due to TS EN 14509.U value converted to American R Value.

Insulation
Material
Yalıtım
Kalınlığı
(mm)
External Steel
(mm)
Internal Steel
(mm)
Weight
(kg/m2)
Span Type
(mm)
Span Distance
1000 1500 2000 2500 3000
Max.Distributed Load (kg/m2)
Polyurethane
(PUR)
40 0,50 0,40 9,65 Two Span 228 179 145 115 x
Multi Span 234 185 152 125 x
50 0,50 0,40 10,05 Two Span 295 235 199 173 x
Multi Span 302 242 202 171 120
60 0,50 0,40 10,45 Two Span 364 292 250 215 131
Multi Span 370 300 255 219 153
80 0,50 0,40 11,25 Two Span 502 410 355 315 225
Multi Span 508 420 363 319 231
100 0,50 0,40 12,05 Two Span 642 531 463 414 320
Multi Span 648 540 473 422 326

Notes:
. Values have been calculated using the allowable “Stress Design” method, taking self weight, imposed loads (wind load) and temperature (Δt=±20ºC) into account.
. If loads are effected as downwards l/200 and l/150 , ıf loads are effected as suction l/150 deflection limits have been used
. Values have been calculated using the steel quality fγ=240 Mpa(Yield Strength).
. In Panel weight calculations, Polyurethane density is taken as 40 kg/m3 and Polyisocyanurate density is taken as 42 kg/m3.